Customization: | Available |
---|---|
After-sales Service: | Online Technical Support |
Warranty: | 18 Months From on Board Day |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item No. | EGL-01A | EGL-02A | EGL-03A | EGL-04A | EGL-05A |
Input Power Supply | Rated DC24V, allowable fluctuation range: DC18~36V | ||||
External Size | 335x165 x80 |
380x110x 80 |
380x110 x80 |
180x180 x80 |
|
Panel Material | Stainless Steel Panel | ||||
Light Material | Acrylic | ||||
Hall Lantern light | white | white | orange | white | white |
Item No. | EGL-06A | EGL-07A | EGL-08A | EGL-09A | EGL-10A |
Input Power Supply | Rated DC24V, allowable fluctuation range: DC18~36V | ||||
External Size | 380x110 x80 |
448x30x 90 |
298x130x 26.5 |
600x55x 90 |
280x125 x117 |
Panel Material | Stainless Steel Panel | ||||
Light Material | Acrylic | ||||
Hall Lantern light | orange | orange | orange | blue | blue |
Test items | Test Conditions | standard test |
High temperature storage | At a high temperature of 70°C, the allowable deviation of the temperature is ±2°C. After the temperature is stable, the high temperature test must be continued for 24h. Then restore the sample under normal test atmospheric conditions, and the minimum recovery time shall not be less than 1h. Then inspect and measure the appearance and electrical performance of the equipment. | The electrical characteristics meet the requirements of the drawings, the parts of the device are not damaged or abnormal, and the display is normal. |
Low temperature storage | At a low temperature of -20ºC, the allowable deviation of temperature is ±2ºC, | The electrical characteristics meet the requirements of the drawings, the parts of the device are not damaged or abnormal, and the display is normal. |
High temperature energized operation | After the temperature is stable, the low temperature test must be continued for 24 hours. | The device can work normally and the display is normal |
Low temperature power-on operation | It is energized and operated at a high temperature of 60°C, the input voltage is DC24V, and the test time is 24h. | The device can work normally and the display is normal |
Alternating damp and heat energized operation | Run at -20ºC low temperature, input voltage DC24V, test | The device can work normally and the display is normal |
Power interference | The test time is 24h. | The device can work normally and the display is normal. |
Static electricity | The temperature changes cyclically between 25±3°C and 40±2°C, and the humidity range is 90%~95%. The input DC24V voltage is energized and the test time is 24h. | Allow the device function or performance to be temporarily reduced or lost, but it can recover on its own. |